yaq/daemons/omega-d8200


bugtracker
source

installation

The omega-d8200 daemon can be installed using the following package managers:

PyPI

traits

The omega-d8200 daemon is composed of the following traits:

is-daemon
is-sensor
uses-serial
uses-uart

hardware

The omega-d8200 daemon has been tested with the following hardware:

omega/d8200

configuration

baud_rate (int) default: 9600
from uses-uart

byte_size (int) default: 8
Byte size of your instrument.

enable (boolean) default: True
Disable this daemon. The kind entry-point will not attempt to start this daemon.
from is-daemon

log_level ({'name': 'level', 'symbols': ['debug', 'info', 'notice', 'warning', 'error', 'critical', 'alert', 'emergency'], 'type': 'enum'}) default: info
Set daemon log-level.
from is-daemon

log_to_file (boolean) default: False
Optionally force logging to a file.
from is-daemon

make (['null', 'string']) default: None
from is-daemon

modbus_address (int) default: 1
Unique address in the modbus network.

model (['null', 'string']) default: None
from is-daemon

parity ({'name': 'parity', 'symbols': ['even', 'odd', 'none'], 'type': 'enum'}) default: none
Modbus parity.

port (int)
TCP port for daemon to occupy.
from is-daemon

serial (['null', 'string']) default: None
Serial number for the particular device represented by the daemon
from is-daemon

serial_port (string)
from uses-uart

stop_bits ({'name': 'stop_bits', 'symbols': ['one', 'one_and_half', 'two'], 'type': 'enum'}) default: one
Number of stop bits.

messages

The omega-d8200 daemon will expose the following public messages:

busy ➜ boolean
Returns true if daemon is currently busy.
from is-daemon

direct_serial_write ➜ null
Expose direct access to the serial port to clients. This should not be encouraged for normal use, but may be very important for debugging. If a device is expected to return data, it should be logged at the INFO level, not returned to the client. This is done to allow long tasks to be run asynchronously, and to explicitly discourage use of this method except when debugging. Setting `busy` to true is encouraged, but individual daemon writers should consider their own use case.
from uses-serial
parameters:

message (bytes)

get_channel_names ➜ {'items': 'string', 'type': 'array'}
Get current channel names.
from is-sensor

get_channel_shapes ➜ {'type': 'map', 'values': {'items': 'int', 'type': 'array'}}
Get current channel shapes. If list is empty, channel is scalar.
from is-sensor

get_channel_units ➜ {'type': 'map', 'values': ['null', 'string']}
Get current channel units.
from is-sensor

get_config ➜ string
Full configuration for the individual daemon as defined in the TOML file. This includes defaults and shared settings not directly specified in the daemon-specific TOML table.
from is-daemon

get_config_filepath ➜ string
String representing the absolute filepath of the configuration file on the host machine.
from is-daemon

get_measured ➜ {'type': 'map', 'values': ['int', 'double', 'ndarray']}
Returns map of channel_name to measured_value. Always returns additional key measurement_id.
from is-sensor

get_measurement_id ➜ {'type': 'int'}
Get current measurement_id. Clients are encouraged to watch for this to be updated before calling get_measured to get entire measurement.
from is-sensor

get_state ➜ string
Get version of the running daemon
from is-daemon

id ➜ {'type': 'map', 'values': ['null', 'string']}
JSON object with information to identify the daemon, including name, kind, make, model, serial.
from is-daemon

shutdown ➜ null
Cleanly shutdown (or restart) daemon.
from is-daemon
parameters:

restart (boolean) default: False


built 2024-02-09 01:44:16                                      CC0: no copyright